Email :David@battery-equipments.com
FAQ
PRODUCTS LIST
products

3/4 Analysis Stations 4 Degas Stations Aperture Analyzer and Surface Area Analyzer

  • Model Number:

    TMAX-3H-2000BET-A
  • Compliance:

    CE certificate
  • Warranty:

    1 year limited warranty with lifetime support
  • Payment:

    T/T, Credit Card, Paypal, LC, Western Union
  • Delivery Time:

    3 days
contact now
DESCRIPTION

3/4 Analysis Stations 4 Degas Stations Aperture Analyzer and Surface Area Analyzer


3H-2000BET-A provides standard sample reference method, single-point and multipoint BET surface area measurements with speed, accuracy, and reliability. Samples having surface areas from 0.01 m2/g to over 1,000 m2/g are easily accommodated.  

The 3H-2000A/BET-A -High Efficiency Surface Area Analyzer

3H-2000BET-A measures surface area using the flowing gas method, which involves the continuous flow of an adsorptive and inert gas mixture over the sample at atmospheric pressure.


The 3H-2000BET-A’s reproducibility is better than 1.5%. The 3H-2000BET-A features a built-in Dewar elevator for completely automated analysis and rewarming fan for rapidly warming the sample tube to increase the speed of the sample analysis.

 

Single injection calibration provides fast start-up and high sample throughput. Specially designed sample holders can be attached and removed from the instrument with one hand. These quick connect/disconnects have a built-in isolation valve to prevent sample contamination.

 

The 3H-2000BET-A features a Dewar support latch system that provides one-handed convenience and safe-guards against LN2 spills. Simple in design, the 3H-2000BET-A requires minimal training time and leaves little chance of operator error. Automatic mode switching for adsorption and desorption is accomplished without operator attention. The low purchase price of the 3H-2000BET-A and its accessories make this instrument one of the most inexpensive ways for a laboratory to begin measuring BET surface area.

 

Features

1. Ultra-stable detector eliminates drift and need for constant readjustment.

2. Cold trap conveniently Recessed at the side of the instrument. This placement reduces the chance of breakage .

3. Single-injection calibration requires only one control setting. Adaptable to any non corrosive adsorbate mix.

4.  All controls and displays are at eye/arm level, out of spill zone.

5.  Built-in sample preparation.

6. The 3H-2000BET-A features a built-in dewar elevator for completely automated analysis and rewarming fan for rapidly warming the sample tube to increase the speed of sample analysis

7. The thermal conductivity detector eliminates temperature-induced drift resulting in highly repeatable results.

8. Single-injection calibration provides fast start-up and high sample throughput.

9. The 3H-2000BET-A features a dewar support latch system that provides one-hand convenience and safeguards against liquid nitrogen spills.


Selection Guide

     

 

3H-2000A

3H-2000BET-A

Degas Stations

4

4

Degas Method

Flow Gas

Flow Gas

Analysis Stations

3

3/4

Standard Sample Reference Method

√ (3 test results in 30min)

√ (3 test results in 30min)

BET

---

√ (4 test results in 150min)

Gas

Mixed gas(20% Nitrogen,80%Helium)

Two bottle of pure gas(Nitrogen and Helium)

Total volume

---

---

Pore Size

---

---

Vacuum Pump

---

---

Cold Trap


Test Reports


 

 battery equipment

Copyright © 2016- Tmax Equipments, Roller Press Machine, Ultrasonic Welder