5V 10A 256-Channel Lithium Cylindrical Cell Grading Tester with Adjustable Cell Tray & Energy Regeneration
- Model Number:
- TMAX-S21-256/10A
- Dimension(L*W*H):
- 1440 L× 500 W× 1840 H
- Compliance:
- CE Certified
- Warranty:
- Two Year Limited Warranty With Lifetime Support
- Place of Origin:
- China
- Shipping Port:
- Xiamen Port
- Payment:
- L/C D/A D/P T/T Western Union
- Delivery Time:
- 5 Days
- Email:
- [email protected]
- WhatsApp:
- +8618659217588
- WeChat:
- 18659217588
Product Description
5V 10A 256-Channel Lithium Cylindrical Cell Grading Tester with Adjustable Cell Tray & Energy Regeneration
Ⅰ.Main Function
- Modularmanufacturing is adopted, with strong universality and easy maintenance.
- Fourwire method is adopted to improve the measurement accuracy.
- Eachbattery channel has a completely independent constant current and voltage source, which forms a loop and does not affect each other.
- Theequipment adopts the control mode of whole machine process transmission.
- Thesampling speed is fast, and the inspection time of the whole cabinet is ≤8s.
- Completewindows platform software with powerful functions, friendly man-machine interface and simple operation. The upper computer can set up to 64 work steps and 256 cycles.
Each formation step can be selected by four attributes: constant current charging, constant voltage charging, constant current discharge and sleep.
- Beable to draw the dynamic curve of each battery in real time, including voltage / time curve, current / time curve, capacity / time curve, energy / time curve, capacity / voltage curve and other functional menus.
- LEDindicator is used to indicate the working state of the battery.
- Communicationmode: TCP / IP.
- Eachupper computer can monitor up to 22 devices.
- Ithas the function of data power failure protection, and can continue to operate when there is an incoming call.
- Thelower computer can work offline for a long time.
- Thesoftware has the functions of file editing and modification of chemical composition and volume separation process library, new monitoring, opening and closing documents, printing and setting.
Ⅱ、Specification
| Model | TMAX-S21-256/ 10A |
| Number of Device Channels | 256 Channels |
| Charge/Discharge Current Range (mA) | 20~10000 |
| Current Measurement Accuracy (mA) | 0. 1%FS |
| Current Resolution (mA) | 1mA |
| Voltage Measurement Range (mV) | 20~4950 |
| Voltage Discharge Range (mV) | 2000~4500 |
| Voltage Measurement Accuracy (mV) | 0. 1%FS |
| Voltage Resolution (mV) | 0 1 |
| Time Measurement Range and Accuracy | 30000 min/work step;
Accuracy±0. 1% |
|
Work Step Content |
Constant current charging, constant current constant voltage charging, constant current discharge, standing. |
| Work Step End Condition | Current, voltage, time, capacity. |
| Maximum Set Number of Steps | 64 |
| Maximum Cycle Settings | 256 |
|
Curve Display |
Charge discharge current curve, charge discharge voltage curve, capacity
curve. |
|
Volume Dividing Mode |
Capacity capacity, time capacity, capacity + curve capacity, time + curve capacity, capacity + voltage capacity, fixed-point voltage capacity. |
|
Protection Mode |
Over current, under current,
over-voltage, under voltage, over capacity and leakage current, in which charging over-voltage / discharging under voltage are protected by hardware and software. |
|
Data Statistics |
Open circuit voltage, average voltage, working time, current, capacity and platform capacity of each battery; Detailed curve and data of each work step; Count the number of batteries in each capacity segment, etc |
| Patrol Inspection Speed (s)
(Time for current and voltage detection of all batteries) |
8 |
| Communication Mode | TCP/IP |
| Number of Devices that can be Controlled by Each Computer | 1~22 |
| Calibration Mode | Automatic calibration with calibration tooling |
| Battery Clamp | Four wire fixture |
| Compatible Battery Height | 0~90mm |
| Battery Clamp Spacing | 70mm |
| Distance Between Bottom Row and Ground | 330mm |
| Equipment Size (mm) (Reference) | 1440 (L)×500 (W)×1840 (H) |
| Total Power of Equipment (KW) | 17 |
|
Power Efficiency |
The charging and discharging power supply adopts energy-saving power supply, and the battery discharge energy is fed back to the power grid.
The maximum efficiency of power charging output shall not be less than 70%, and the maximum efficiency of power recovery shall not be less than 65% |
| Equipment Stability | The equipment has good long-term operation stability. After precision calibration, it shall not exceed the agreed precision control range within 6 months. |
| Working Power Supply | Three phase AC380V ± 5% 50Hz |
Ⅲ、AC / DC Bidirectional Power Supply
The equipment power supply adopts energy-saving AC / DC bidirectional power supply with high charging efficiency, and the battery discharge energy is fed back to the power grid.
Part of the battery discharge energy is used by the power supply itself, the other part is used by other charging equipment, and the rest is fed back to the power grid for other equipment.