5V100A 8 Channels Lithium ion Battery Tester Machine For Battery Charge and Discharge Analysis 


 

Technical parameter

Indicator items

Indicator parameters

Equipment model

TMAX-5V100A-8CH

Equipment specifications

5V/100A

Number of device channels

8

Channel control mode

Independent control for each channel, current and voltage four wire system acquisition

Channel characteristics

The constant current source and constant voltage source adopt a dual closed-loop structure

Input impedance

≥ 1M Ω

Voltage

Range

Charge

10mV-5V (device port)

Discharge

2V-5V (device port), minimum discharge voltage depends on line length

Accuracy

±0.1% of FS, RT15℃-35℃

Current

Range

Charge

200mA-100A

Discharge

200mA-100A

Accuracy

±0.1% of FS , RT15℃-35℃

Power

Single channel output power

500W

Stability

0.2% of FS

Time

Current response time

≤100ms

Data record

Record frequency

1Hz

Data recording conditions

Minimum time interval: 1 second

Minimum voltage interval: 1mV

Minimum current interval: 10mA

Charge

Charging mode

Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging

Deadline conditions

Voltage, current, relative time, capacity, - △ V

Discharge

Discharge mode

Constant current discharge, constant power discharge, constant resistance discharge

Deadline conditions

Voltage, current, relative time, capacity, - △ V

Pulse mode

 

Optional

charging

Constant current mode, constant power mode

discharge

Constant current mode, constant power mode

Minimum pulse width

Suggest 5S or above

Deadline conditions

Voltage, relative time

Indicator items

Indicator parameters

DCIR

DCIR (optional)

Support custom point extraction for DCIR calculation

Cycle

Loop testing

Can set 399 commands and 65535 loops

Loop nesting

Supports 5 layers of nested loops

Protection

Software protection

Support power-off data protection

Support for continuous startup (with UPS power supply)

Overvoltage protection, undervoltage protection, capacity protection, overcurrent protection, undercurrent protection

Anti reverse connection protection

Data export method

ExcelPDF

Cooling method

Air cooling

Equipment noise

≤60dB

Communication method with upper computer

Network 

system requirements

Windows XP and above versions

 

Environmental requirements

Indicator items

Indicator parameters

Working temperature range

0 ℃ -40 ℃

Storage temperature range

-10 ℃ -50 ℃

Relative humidity of working environment

≤ 70% RH (without water vapor condensation)

Relative humidity of storage environment

≤ 80% RH (without water vapor condensation)

Input power supply

AC220V ± 10%/50Hz,

Clamp type

Choose one of the polymer clamp or crocodile clamp as required

 


 

 battery equipment

Copyright © 2016- Tmax Equipments, Roller Press Machine, Ultrasonic Welder